Thermal upgrades just reached the wall. Literally.

Insulation without stripping the old layer, without piles of rubble, without turning your home into an EPS bunker. A thin-film thermal-insulation coating for walls, roofs, and facades - applied to what you already have.

The wall loses heat in winter, the roof heats up in summer, the bills keep rising - and conventional insulation means scaffolding, a dozen-plus centimeters of EPS foam, rubble, and weeks of work. IzolPlus solves the same problem differently:

Thin layer
a coating just over 1 mm thick that adds insulation without thickening the wall
No teardown
applied to the existing wall, roof, and facade
No downtime
sprayed or rolled on, the building keeps working

Six coatings, one goal.

One thermal-insulation line, six surfaces. Each coating is matched to a different place in the building - from the roof to the pipes.

01 / Bitum

Bitum

For roofs: roofing felt, sheet metal, shingles.

  • Spray-on coating, applied in two layers.
  • Reflects solar energy before it heats the roof.
  • PZH hygiene certificate.
Parameter Value
Thermal conductivity λ 0.00079 W/m·K MDPI Energies 2022 · DOI 10.3390/en15176286
Solar energy reflected (TSR) 86.95% MDPI Energies 2022 · DOI 10.3390/en15176286
Fire class (NRO) C-s1-d0 PN-EN 13501-1
Application spray-on, two-layer
02 / Termo-Fasada

Termo-Fasada

For facades.

  • A thin layer instead of a dozen-plus centimeters of EPS foam.
  • Any color - NCS and RAL palette.
  • Does not change the shape of the building or the window sills.
Parameter Value
Thermal conductivity λ 0.00079 W/m·K
Standard CE PN-EN 15824:2017
Warranty up to 15 years
03 / Termo-Wnętrze

Termo-Wnętrze

For walls from the inside.

  • Applied from the inside - without touching the facade.
  • PZH hygiene certificate, approved for hospitals.
  • Eliminates cold spots and condensation.
Parameter Value
Thermal conductivity λ 0.00079 W/m·K
Floor-to-ceiling difference ±2°C Łomża project 2023
04 / Grunt

Grunt

Substrate preparation for IzolPlus coatings.

  • Prepares the substrate for the actual IzolPlus coating.
  • Determines the adhesion and durability of the finish.
05 / Tynk

Tynk

A thin-film thermal-insulation render.

  • Thermal insulation hidden in the render layer.
  • Works on its own or together with thinner EPS foam.
Parameter Value
Thermal conductivity λ 0.00079 W/m·K
Typical thickness 1.8 mm
06 / TERMO STOP

TERMO STOP

For installations: pipes, junctions, valves.

  • Technical compound for pipes, junctions, and fittings.
  • Lowers the temperature of hot surfaces.
  • Reduces heat loss from installations.
Parameter Value
Steam valve (surface) 210°C → 44°C GPEC Gdańsk
System thermal conductivity λ 0.000432 W/m·K
Energy gain >85%

A thermal shield, not a thick blanket.

Traditional insulation slows heat loss with thickness. IzolPlus reflects heat and slows its conduction - in a layer measured in millimeters, not centimeters.

White IzolPlus coating reflecting sunlight on a hall roof
/ 01

Reflects the sun's heat

Densely packed microspheres form a barrier that reflects solar energy instead of letting it into the wall. In summer the roof and wall heat up much more slowly.

86.95% of solar energy reflected (TSR)

MDPI Energies 2022 · DOI 10.3390/en15176286

Termo-Fasada coating on a building facade
/ 02

Slows heat loss

Inside each microsphere, trapped gas works like a thermos - it strongly slows heat flow through the wall. In winter the heat stays inside.

0.00079 λ W/m·K - the lower, the better

MDPI Energies 2022 · DOI 10.3390/en15176286

Five situations, five solutions.

Pick your case - we'll match the product and show you what to expect.

Your problem
Solution
What to expect
Step
/ Upgrade

I already have EPS foam, but the house still loses heat

The old insulation has settled, with thermal bridges and damp in the corners.

Termo-Fasada on the facade and Termo-Wnętrze from the inside - without stripping the old insulation.

Thermal bridges removed and wall temperatures evened out.

reference projects

/ New building

I am building or finishing a house

I want good insulation without thickening the walls or changing the shape.

Target build-up: thermal-insulating plaster as the adhesive + 10 cm of EPS + facade coating over 1 mm.

Better parameters than 20 cm of EPS alone - at half the thickness.

Adalio recommended build-up

/ From the inside

I have cold walls and damp from the inside

Cold spots, condensation, mold - and I cannot touch the facade (e.g. a heritage building).

Termo-Wnętrze - paint applied from the inside, with a PZH hygiene certificate.

Tenement from 1898 in Łomża: the floor-to-ceiling difference dropped to ±2°C, the cold spots disappeared.

project completed 2023

/ Roof

The roof gets unbearably hot in summer

The attic or hall overheats and the air conditioning cannot keep up.

Bitum - a spray-on coating for roofing felt, sheet metal, and shingles.

The AAM Driveline hall roof went from 71-86°C down to 17-21°C in full sun.

AAM Driveline 2023, thermal imaging

/ Installations

I have hot pipes and installations

Pipelines, junctions, and valves lose heat and pose a burn risk.

TERMO STOP - a technical compound for pipes, junctions, and fittings.

A steam valve at 210°C on the surface dropped to 44°C.

GPEC Gdańsk

Half the thickness. Better parameters.

A millimeter of coating will not replace 20 cm of EPS - and it does not have to. The IzolPlus build-up combines three layers that each insulate, and as a whole it delivers better parameters than classic 20 cm.

IzolPlus build-up plaster-adhesive + 10 cm EPS + coating
Classic insulation 20 cm of EPS
Insulation thickness on the wall
IzolPlus build-up plaster-adhesive + 10 cm EPS + coating approx. 10 cm + coating over 1 mm
Classic insulation 20 cm of EPS 20 cm
Insulation parameters system as a whole
IzolPlus build-up plaster-adhesive + 10 cm EPS + coating better - three layers insulate together
Classic insulation 20 cm of EPS reference point
Adhesive under the EPS does it insulate?
IzolPlus build-up plaster-adhesive + 10 cm EPS + coating thermal-insulating plaster - insulates itself
Classic insulation 20 cm of EPS standard adhesive - does not insulate
Thermal bridges at board joints freezing
IzolPlus build-up plaster-adhesive + 10 cm EPS + coating eliminated by the plaster-adhesive layer
Classic insulation 20 cm of EPS board contact points freeze through
Reshaping and window sills scope
IzolPlus build-up plaster-adhesive + 10 cm EPS + coating smaller - approx. 10 cm
Classic insulation 20 cm of EPS full - 20 cm

Build-up order: thermal-insulating plaster as the EPS adhesive first, then classic 10 cm EPS, finished with a facade coating over 1 mm. The plaster-adhesive itself insulates, so EPS board joints do not freeze through the way they do with standard adhesive. The result: better parameters than 20 cm of EPS alone - at half the thickness.

/ Proof from the site

Every coating starts with a thermal-imaging measurement - before and after.

See projects →

/ Reference measurement

AAM Driveline roof: 42°C difference versus a roof without the coating.

AAM Driveline · Świdnica June 2023, testo 872s camera
See the project
±2°C floor-to-ceiling

The cold spots are gone. The temperature evened out - the floor-to-ceiling difference is no more than 2°C.

Tenement from 1898 · IzolPlus Termo-Wnętrze · Łomża · 2023

Check your building. No obligation.

We come over, take a thermal image, and show you where money is leaking out. The audit is free.

Indicative values. The audit gives concrete numbers for your building.